Anti-bacterial Effect
Here is data which shows anti-bacterial effect by BW water reforming device. We compared viable bacteria count of the water to which colitis germ is inoculated.
Blue is BW reformed water using BW Ω device, and Red is tap water. Number of colitis germ was counted right after colitis germ was inoculated, and after 8 hours and after 24 hours.
Number of colitis germ became almost zero with BW reformed water.
Right after inoculation | After 8 hours | After 24 hours | |
---|---|---|---|
Tap water | 104000 | 15000 | 24000 |
BW reformed water | 77000 | 1 | 1 |
Anti-bacterial Effect Test Data
Case 1:Measurement of number of common bacteria (by Applied Chemistry Department, Kanagawa Institute of Technology)
Asst. Professor Mr. Jyunsuke Sawai, Applied Chemistry Dept. , Kanagawa Institute of Technology
Number of common bacteria was counted with BW reformed water, tap water, distilled water and sterilized distilled water.
No common bacteria grew after a week.(though tap water had bacteria after 4 days.
Date of inspection
March 23, 2000
Sample
(1)Reformed water by BW reformation device
(2)Tap water
(3)Distilled water
(4)Sterilized distilled water
Small amount of each sample was picked up and number of common bacteria was counted by the colony count method. (Used a standard agar medium of Eiken Chemical)
Test result
Start | After 1day | After 2days | After 3days | After 4days | After 5days | After 6days | |
---|---|---|---|---|---|---|---|
BW reformed water | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Tap water | 0 | 0 | 0 | 0 | 0 | 3000 | 8000 |
Distilled water | 500 | 1000 | 13000 | 14000 | 21000 | 20000 | 26000 |
Sterilized distilled water | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
(1)BW Reformed water No bacteria was detected
(2)Tap water Bacterial was generated after 5 days
(3)Distilled water Bacterial was generated immediately
(4)Sterilized distilled water No bacteria was detected
Case 2:Measurement of Legionella and O-157 at Kitasato Research Center for Environmental Science
By Ms. Ritsuko Kikuchi of Kitasato Research Center for Environmental Science
It was confirmed that BW reformed water has antibacterial power against legionella approximately 5 times of tap water. BW reformed water has antibacterial power against O-157 bacteria approximately 4 times of tap water.
Date of inspection
July 2000
Samples
(1)Tap water (2)Reformed water by BW water reforming device
Test method
Put (1) and (2)water into 1.e glass bottles, and inject legionella and O-157 bacteria. Place each bottle still with 3 meters away each other. And, count number of colony of each bacteria right after water is put in, and 1 day later and 2 days later, total 3 times.
Test result
Start | After 1 day | After 2 days | |
---|---|---|---|
Legionella ATCC #33153 reformed water | 460000 | 700 | 24000 |
Legionella ATCC #33153 Tap water | 460000 | 160000 | 120000 |
0-157 ATCC #35150 reformed water | 45000 | 53000 | 28000 |
0-157 ATCC #35150 Tap water | 48000 | 50000 | 110000 |
Start | 1 days later | 2 days later | |
---|---|---|---|
Legionella ATCC #33153 reformed water | No difference | Drastically reduced | Reduced to 5% |
Legionella ATCC #33153 Tap water | No difference | Reduced by 35% | Reduced to 26% |
0-157 ATCC #35150 reformed water | Reduced by 6% | Increased by 17 % over previous day | Reduced by 47% compared to previous day |
0-157 ATCC #35150 Tap water | No difference | Increased by 4 % over previous day | Increased by 120% compared to previous day |
- BW reformed water has antibacterial power against legionella approximately 5 times of tap water.
- BW reformed water has antibacterial power against O-157 bacteria approximately 4 times of tap water.
Case 3:Ice plant in Osaka: Measured number of common bacteria
Aquapia Co., Ltd. in Osaka prefecture
Anti-bacteria effect by BW reformed water was confirmed for ice plant using pure water. BW reformed water showed about 3 times of anti-bacteria effect in four days compared with pure water.
Comparisons of number of bacteria with and without BW water reforming device
1 day later | 2 days later | 3 days later | 4 days later | |
---|---|---|---|---|
Osaka ice plant water 36℃ | 196 | 1400 | 1400 | 2000 |
Kashiwabara ice plant BW reformed water 36℃ | 155 | 21 | 41 | 624 |
Case 4:A Sake brewing company in Niigata prefecture Stop using preservatives and installed BW water reforming device
Asahi-Shuzo Sake Brewing Co., Ltd.
This is a case of long-established Sake Brewing Company. Cooling water pipe is installed in the plant for temperature control which is important for sake storage and maturing. When they stop putting in preservatives for water environmental preservation, the alarm of the refrigerator rings frequently. Each time alarm rings, two persons clean the strainer for two hours. To eliminate this work, BW water reforming device was installed. Three months after the installation of BW device, scale with high viscosity became smooth and could be washed away by water. The alarm of the refrigerator never rang thereafter.
(Excerpt from the public relations magazine of Azbil Trading Co., Ltd.)
Case 5:Yield rate improvement in hydroponic culture
Disposal rate of tulip bulb for hydroponic culture was about 13%.
Its breakdown was 1~2% at incoming, 3% due to fungi during storage, 3% due to sprouting or rooting defects, 6% due to poor budding.
When water for hydroponic culture was improved using BW water reforming device, all the bulbs sprouted, which never happened before.
Tulips grew up well, and yield rate became almost 100%
Case 6:Life of water-soluble cutting oil was extended by 3 times more with BW reformed water
Test period
From August 5, 2008 to November 28, 2008
(Measurement was done at 1:00 p.m. every Tuesday and Friday by a senior engineer with more than 20 years of experience in metal processing.)
Factory location
Two in Tohoku area and one in Kansai area.
Machines used
CNC machine tools in Matsuura machining center, Mori CNC lathe machine, Mazac machining center, Okuma NC lathe machine.
Measurer reported in 11 items below.
Checked point | Better result with BW water | Not sure | Better with tap water |
---|---|---|---|
Stains around machinery | 80.9% | 19.1% | 0% |
Slide oil condition on cutting oil surface | 89% | 11.0% | 0% |
Sludge level in cutting oil tank | 41.3% | 58.7% | 0% |
Breeding condition of bacteria | 67.7% | 32.3% | 0% |
Intensity of odor | 45.4% | 54.6% | 0% |
Ph change of cutting oil (degradation and life) | 22.0% | 78.0% | 0% |
Change of cutting efficiency | 32.4% | 67.6% | 0% |
Condition of cutting surface | 76.8% | 22.2% | 0% |
Quality retention of cutting blade | 93.0% | 7.0% | 0% |
Quality retention of cutting work (rust after 3 weeks) | 77.8% | 23.2% | 0% |
Ease of cleansing cutting works | 98.0% | 2.0% | 0% |
With installation of BW water reforming device, Aldehyde-based deteriorated product was reduced to 1/3 .(from NMR data by Kanagawa Institute of Industrial Technology Center)
No more odor, remarkable antibacterial power !
Cost saving of max. 672,000 Yen.
After 2 months | |
---|---|
BW reformed water | <1 |
Tap water | 4.3×10⁴ |
BW water reformation device :Summary of other solutions
- Reduction of sludge exhausted by buildings & factories →Cost reduction of sludge processing
- Improvement of cleansing power →Cost reduction by less amount of cleansing liquid and environmentally friendly
- Improvement of contamination from industrial waste water →Improvement of ocean environment and friendly to the earth
Work period is very short for BW water reforming device, because the device can be installed in water pipe. BW water reforming device can be installed in any kinds of buildings such as plant, factory, house, etc. Also, its effect is semi-permanent and maintenance cost can be reduced because the device needs to be installed only once in water supply pipe.
Please check conditions of your building or factory first.